Homepage | Set Home | Add to Favorites
Member

Beijing Hyliton Power Technology Co.,Ltd


Search
 

Friends links
  • No link

Browse by Showcase | Browse by List Products
Picture Heading Updated
LV Reactive Power Compensation
Low Voltage Reactive Power Compensation Unitserie is an integrated power distribution product gathering the functions of power distribution, measurement, protection, control and compensation, which installed at the low-voltage side of the transformers. It
2017-09-22
24 kV Current Transformers
LDZC-24 high precision current transformer is suitable for current measurement and protection of distribution equipments in 24kV AC power system. It is widely used in compact fully insulated ring main unit such as Safe Ring/Safe Plus, RM6/SM6, SVS, GA/GE,
2017-09-16
Dual Cable Current Transformers
LDZC135-10/24 current transformer that is designed for double cable is suitable for AC power system of rated voltage 10kV. Especially for double cable inlet and outlet in power supply system. the Combination Modes can be flexibly chosen among metering, me
2017-09-14
Indoor Voltage Transformers
Technical data:· The product performance is in accordance with GB1207 and IEC60044-2 standards · Rated insulation level 3.6/20/45 kV· Rated frequency 50Hz or 60Hz· Ambient temperature –25℃~+40℃· Altitude: Up to 1000m above sea level· Indoor device...
2017-09-08
W Type Current Transformers
General description: W type for the current transformer is SEG company WIC1 type self-supply protection device of special current transformer can provide for WIC1 measuring current and work power. Test winds can be directly verified protect windings setti
2017-09-04
Outdoor Current Transformers
Technical data: ● The product performance is in accordance with GB1208 and IEC60044-1 standards ● Rated insulation level 40.5/95/185 kV ● Rated frequency 50Hz or 60Hz ● Rated secondary current 5A or 1A ● Ambient temperature –25℃~+40℃ ● Altitude:Up to 1000
2017-08-19
Combined Current And Voltage Transformers
JLSZ-10 Combined Instrument Transformer Brief introduction The current and voltage combined type instrument transformer is used in power system of 50Hz or 60 Hz rated frequency, 1KV and below rated voltage, for energy measurement. Type designation Technic
2017-08-16
Feeder Remote Terminal Units
According to integrated domestic and foreign advanced technology, the actual demand of the power distribution area, PSW200 Ring Main Unit boundary switch controller is the latest development of the company's new generation watchdog controller. The equipme
2017-08-15
   Home   Next   Previous   Last